Our residual circuit breakers (RCBO) now have the slimmest design in the world, making it incredibly efficient, as well as practical for smaller spaces. Residual circuit breakers are suitable for both residential and commercial applications, and serve the purpose of protecting against short circuits and overloaded sockets.

Clipsal Industrial RCBO with Tail (3)

Clipsal Industrial Single Pole RCD / MCB, 10A, 240VAC, 10kA with Tail
<p><strong style="font-size: 13px;">DESCRIPTION</strong><br style="font-size: 13px;" /> <br style="font-size: 13px;" /> <span style="font-size: 13px;">SINGLE POLE RCD / MCB, 10A, 240VAC.</span><br style="font-size: 13px;" /> <br style="font-size: 13px;" /> <span style="font-size: 13px;">CLIPSAL MAX 4 - COMBINATION RESIDUAL CURRENT DEVICES AND MINIATURE CIRCUIT BREAKERS - 1 MODULE WIDE ELECTRONIC COMBINATION RCD / MCB'S NON-DELAYED SUITABLE FOR SOME CLIPSAL CONSUMER PLASTIC SWITCHBOARDS 240V 10A - 30MA 1-PHASE - 10KA - 1 MODULE WIDE.</span><br /> <br /> &nbsp;</p> <p style="font-size: 13px;"><span style="color: rgb(0, 0, 0); font-family: Arial, Helvetica, sans-serif; font-size: 12px;">Product Code: 4RCBE120/30C10</span></p> <p style="font-size: 13px;">Approx. Dimensions:&nbsp;(&nbsp;10cm x&nbsp;&nbsp; 8cm x&nbsp;&nbsp; 6cm)</p> <p style="font-size: 13px;">Approx. Weight:&nbsp;&nbsp;(0.4&nbsp;&nbsp;kg)<br /> <br /> <strong>SPECIFICATIONS</strong></p> <table border="0" cellpadding="0" cellspacing="0" style="border: 1px dotted rgb(211, 211, 211); font-size: 13px; width: 505px;" width="505"> <tbody> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Leakage current type:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>A</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Number of poles (total):</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>1</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Rated current:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>10A</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Rated fault current:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>.03A</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Rated short-circuit breaking capacity EN 60898:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>10kA</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Rated voltage:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>240V</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Release characteristic:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>C</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Surge current capacity:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>6kA</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>UNSPSC:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>39121600</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Voltage type:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>AC</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Width in number of modular spacings:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>.03</p> <div>&nbsp;</div> </td> </tr> </tbody> </table> <p>&nbsp;</p>
25.00
Clipsal Industrial Single Pole RCD / MCB, 16A, 240VAC, 10kA with Tail
<p style="font-size: 13px;"><strong>DESCRIPTION</strong><br /> <br /> SINGLE POLE RCD / MCB, 16A, 240VAC.<br /> <br /> CLIPSAL MAX 4 - COMBINATION RESIDUAL CURRENT DEVICES AND MINIATURE CIRCUIT BREAKERS - 1 MODULE WIDE ELECTRONIC COMBINATION RCD / MCB'S NON-DELAYED SUITABLE FOR SOME CLIPSAL CONSUMER PLASTIC SWITCHBOARDS 240V 16A - 30MA 1-PHASE - 10KA - 1 MODULE WIDE.</p> <p style="font-size: 13px;">Approx. Dimensions:&nbsp;(&nbsp;10cm x&nbsp;&nbsp; 8cm x&nbsp;&nbsp; 6cm)</p> <p style="font-size: 13px;">Approx. Weight:&nbsp;&nbsp;(0.4&nbsp;&nbsp;kg)<br /> <br /> <strong>SPECIFICATIONS</strong></p> <table border="0" cellpadding="0" cellspacing="0" style="border: 1px dotted rgb(211, 211, 211); font-size: 13px; width: 505px;" width="505"> <tbody> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Leakage current type:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>A</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Number of poles (total):</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>1</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Rated current:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>16A</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Rated fault current:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>.03A</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Rated short-circuit breaking capacity EN 60898:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>10kA</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Rated voltage:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>240V</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Release characteristic:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>C</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Surge current capacity:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>6kA</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>UNSPSC:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>39121600</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Voltage type:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>AC</p> </td> </tr> <tr> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>Width in number of modular spacings:</p> </td> <td style="border: 1px dotted rgb(211, 211, 211);"> <p>.03</p> </td> </tr> </tbody> </table>
25.00
Clipsal Industrial Single Pole RCD / MCB, 20A, 240VAC, 10kA with Tail
<p><strong>DESCRIPTION</strong><br /> <br /> SINGLE POLE RCD / MCB, 20A, 240VAC.<br /> <br /> CLIPSAL MAX 4 - COMBINATION RESIDUAL CURRENT DEVICES AND MINIATURE CIRCUIT BREAKERS - 1 MODULE WIDE ELECTRONIC COMBINATION RCD / MCB'S NON-DELAYED SUITABLE FOR SOME CLIPSAL CONSUMER PLASTIC SWITCHBOARDS 240V 20A - 30MA 1-PHASE - 10KA - 1 MODULE WIDE.</p> <p>Approx. Dimensions:&nbsp;(&nbsp;10cm x&nbsp;&nbsp; 8cm x&nbsp;&nbsp; 6cm)</p> <p>Approx. Weight:&nbsp;&nbsp;(0.4&nbsp;&nbsp;kg)<br /> <br /> <strong>SPECIFICATIONS</strong></p> <table border="0" cellpadding="0" cellspacing="0" style="width:505px;" width="505"> <tbody> <tr> <td> <p>Leakage current type:</p> </td> <td> <p>A</p> </td> </tr> <tr> <td> <p>Number of poles (total):</p> </td> <td> <p>1</p> </td> </tr> <tr> <td> <p>Rated current:</p> </td> <td> <p>20A</p> </td> </tr> <tr> <td> <p>Rated fault current:</p> </td> <td> <p>.03A</p> </td> </tr> <tr> <td> <p>Rated short-circuit breaking capacity EN 60898:</p> </td> <td> <p>10kA</p> </td> </tr> <tr> <td> <p>Rated voltage:</p> </td> <td> <p>240V</p> </td> </tr> <tr> <td> <p>Release characteristic:</p> </td> <td> <p>C</p> </td> </tr> <tr> <td> <p>Surge current capacity:</p> </td> <td> <p>6kA</p> </td> </tr> <tr> <td> <p>UNSPSC:</p> </td> <td> <p>39121600</p> </td> </tr> <tr> <td> <p>Voltage type:</p> </td> <td> <p>AC</p> </td> </tr> <tr> <td> <p>Width in number of modular spacings:</p> </td> <td> <p>.03</p> </td> </tr> </tbody> </table>
25.00

RCBO (7)

Tesla 1P 20A 6kA RCBO (ESV APPROVED)
<ul style="font-size: 13px;"> <li>Tesla 20&nbsp;Amp RCBO</li> <li>DIN Rail Mounted</li> <li>1 Module 18mm Wide</li> <li>Rated 6kA</li> <li>Full Australian Approvals SAA-151653-EA</li> <li>ESV Approved</li> <li>5 Year Warranty</li> </ul>
23.00
Tesla 1P 16A 6kA RCBO (ESV APPROVED)
<ul> <li>Tesla 16 Amp RCBO</li> <li>DIN Rail Mounted</li> <li>1 Module 18mm Wide</li> <li>Rated 6kA</li> <li>Full Australian Approvals SAA-151653-EA</li> <li>ESV Approved</li> <li>5 Year Warranty</li> </ul>
23.00
Tesla 1P 10A 6kA RCBO (ESV APPROVED)
<ul> <li>Tesla 10&nbsp;Amp RCBO</li> <li>DIN Rail Mounted</li> <li>1 Module 18mm Wide</li> <li>Rated 6kA</li> <li>Full Australian Approvals SAA-151653-EA</li> <li>ESV Approved</li> <li>5 Year Warranty</li> </ul>
23.00
DL 1P 32A 4.5kA RCBO Combo (ESV Approved, 3rd Generation)
<p>The DL 4.5ka RCBO's are the most reliable RCBO's you can get in the market so why risk anything less. They have been approved by Energy Safe so you can be confident installing it. Over the last several years we have sold tens of thousands of RCBO'S and we still have not received any returns.<br /> <br /> Functions of a combination of circuit breaker and residual current device, protects you from the fault of electricity because of over-current and short circuit earth fault current. It is self-protecting up to a maximum short-circuit of 32AMP. All breaking capacities comply with standard IEC/EN61009.</p> <p>You can put load either up or down which will save you time upon installation</p> <p><br /> <strong>Construction and Features</strong><br /> Installation Type: III<br /> Installation on 35mm standard DIN rail<br /> Built to avoid obvious shock or vibration<br /> <br /> <strong>Technical Data</strong><br /> <br /> Standard: IEC61009-1<br /> Rated Breaking Capacity: 4500A<br /> Voltage and Frequency: 240V, 50/60Hz<br /> Rated Current: 32A<br /> Rated Tripping Current I△n:30,100mA<br /> Max Breaking Times: 0.1S<br /> Mechanical Life: 10000 times<br /> Electrical Life: 1500 Times<br /> Usage Types: AC-22<br /> Protection Grade: IP20<br /> Max Cable: Size: 25mm2<br /> <br /> <strong>COMES WITH 3 YEAR WARRANTY<br /> AUSTRALIAN APPROVED&nbsp;<br /> ESV APPROVED<br /> 3RD GENERATION MODEL</strong></p>
17.50
DL 1P 20A 6kA RCBO Combo (ESV Approved, 3rd Generation)
<p><br /> <span style="padding-left:10px;">The DL 6kA RCBO's are the most reliable RCBO's you can get in the market so why risk anything less. They have been approved by Energy Safe so you can be confident installing it. </span>Over the last several years we have sold tens of thousands of RCBO'S and have one of the best return rates in the market.&nbsp;<br /> <br /> <span style="line-height: 1.6em;">Function's of a combination of circuit breaker and residual current device, protect's you from the fault of electricity because of over-current and short circuit earth fault current. It is self-protecting up to a maximum short-circuit of 20AMP. All breaking capacities comply with standard IEC/EN61009.</span></p> <p><span style="line-height: 1.6em;">You can put load either up or down which will save you time upon installation</span></p> <p><strong>FEATURES</strong><br /> <br /> -&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The slimmest 6kA RCBO in the world - the newest design compared with competitors.</p> <p>-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Genuine 6kA fault level- declared after hundreds of seriously passed tests. Suits both residential and commercial applications.</p> <p>-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Top and bottom line and load compatible- newest design for ease of installation.</p> <p>-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Two pole safety feature allows switching of both Active and Neutral contacts - Active contacts always connect earlier and break later;</p> <p>-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Type A RCBO protection guarantees complete safety</p> <p>-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Single module is ideal to save valuable switchboard space.</p> <p>-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 10 years R &amp; D, wholly protected</p> <p>-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Easy to retrofit a MCB with RCBO</p> <p>-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; No flying leads<br /> <br /> <strong style="font-size: 13px; line-height: 20.8px;">COMES WITH 3 YEAR WARRANTY</strong><br /> <strong>AUSTRALIAN APPROVAL NUMBER: AS/NZS 61009.1 SAA APPROVAL: 120946EA<br /> <br /> 3RD GENERATION MODEL&nbsp;<br /> ESV APPROVED</strong></p>
19.50
DL 1P 16A 6kA RCBO Combo (ESV Approved, 3rd Generation)
<p style="font-size: 13px; line-height: 20.8px;"><br /> <span style="padding-left: 10px;">The DL 6kA RCBO's are the most reliable RCBO's you can get in the market so why risk anything less. They have been approved by Energy Safe so you can be confident installing it.&nbsp;</span>Over the last several years we have sold tens of thousands of RCBO'S and have one of the best return rates in the market.&nbsp;<br /> <br /> <span style="line-height: 1.6em;">Function's of a combination of circuit breaker and residual current device, protect's you from the fault of electricity because of over-current and short circuit earth fault current. It is self-protecting up to a maximum short-circuit of 20AMP. All breaking capacities comply with standard IEC/EN61009.</span></p> <p style="font-size: 13px; line-height: 20.8px;"><span style="line-height: 1.6em;">You can put load either up or down which will save you time upon installation</span></p> <p style="font-size: 13px; line-height: 20.8px;"><strong>FEATURES</strong><br /> <br /> -&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The slimmest 6kA RCBO in the world - the newest design compared with competitors.</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Genuine 6kA fault level- declared after hundreds of seriously passed tests. Suits both residential and commercial applications.</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Top and bottom line and load compatible- newest design for ease of installation.</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Two pole safety feature allows switching of both Active and Neutral contacts - Active contacts always connect earlier and break later;</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Type A RCBO protection guarantees complete safety</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Single module is ideal to save valuable switchboard space.</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 10 years R &amp; D, wholly protected</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Easy to retrofit a MCB with RCBO</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; No flying leads<br /> <br /> <strong style="font-size: 13px; line-height: 20.8px;">COMES WITH 3 YEAR WARRANTY</strong><br /> <strong style="font-size: 13px; line-height: 20.8px;">AUSTRALIAN APPROVAL NUMBER: AS/NZS 61009.1 SAA APPROVAL: 120946EA<br /> <br /> 3RD GENERATION, ESV APPROVED</strong></p>
19.50
DL 1P 10A 6kA RCBO Combo (ESV Approved, 3rd Generation)
<p style="font-size: 13px; line-height: 20.8px;"><br /> <span style="padding-left: 10px;">The DL 6kA RCBO's are the most reliable RCBO's you can get in the market so why risk anything less. They have been approved by Energy Safe so you can be confident installing it.&nbsp;</span>Over the last several years we have sold tens of thousands of RCBO'S and have one of the best return rates in the market.&nbsp;<br /> ​<br /> <span style="line-height: 1.6em;">Function's of a combination of circuit breaker and residual current device, protect's you from the fault of electricity because of over-current and short circuit earth fault current. It is self-protecting up to a maximum short-circuit of 20AMP. All breaking capacities comply with standard IEC/EN61009.</span></p> <p style="font-size: 13px; line-height: 20.8px;"><span style="line-height: 1.6em;">You can put load either up or down which will save you time upon installation</span></p> <p style="font-size: 13px; line-height: 20.8px;"><strong>FEATURES</strong><br /> <br /> -&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The slimmest 6kA RCBO in the world - the newest design compared with competitors.</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Genuine 6kA fault level- declared after hundreds of seriously passed tests. Suits both residential and commercial applications.</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Top and bottom line and load compatible- newest design for ease of installation.</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Two pole safety feature allows switching of both Active and Neutral contacts - Active contacts always connect earlier and break later;</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Type A RCBO protection guarantees complete safety</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Single module is ideal to save valuable switchboard space.</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 10 years R &amp; D, wholly protected</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Easy to retrofit a MCB with RCBO</p> <p style="font-size: 13px; line-height: 20.8px;">-&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; No flying leads<br /> <br /> <strong style="font-size: 13px; line-height: 20.8px;">COMES WITH 3 YEAR WARRANTY</strong><br /> <strong style="font-size: 13px; line-height: 20.8px;">AUSTRALIAN APPROVAL NUMBER: AS/NZS 61009.1 SAA APPROVAL: 120946EA<br /> <br /> 3RD GENERATION, ESV APPROVED</strong></p>
19.50